The short answer Check the thermostat fan setting and the air filter first. A fan set to On blows unheated air between cycles, and a clogged filter makes a furnace overheat and shut its burners off while the fan keeps running. Those two account for a lot of “cold air” calls.

Time
10 minutes
You’ll need
A new filter, a flashlight
Cost
The price of a filter

These apply to both kinds of heat common around Houston: gas furnaces and electric heat. Where the two differ, the step says so.

  1. Check the thermostat

    Set it to Heat, a few degrees above the room temperature, with the fan on Auto. With the fan on On, the blower runs nonstop, and between heating cycles that air is not warmed.

    If the screen is blank or dim, replace the batteries.

  2. Give it two minutes

    A furnace lights its burners before it starts the fan, and the first air out has been sitting in ducts in a cold attic. Cool air for the first minute or so is normal. Cool air after five minutes is not.

  3. Replace the filter

    A clogged filter traps heat inside the furnace. A safety switch then shuts the burners or heating elements off to protect the equipment, but the fan keeps running to cool it down. The result is a heater that runs and blows cold.

    Put in a clean filter, turn the system off at the thermostat for five minutes, then try again.

  4. Check every breaker

    Electric heat: the heating elements usually have their own breaker, sometimes two, separate from the fan. If one has tripped, the fan runs with no heat behind it. Reset it once.

    Gas furnace: check the furnace breaker and the switch on or near the unit that looks like a light switch. It gets turned off by accident.

  5. Gas furnace: check the gas

    Is the gas stove or water heater working? If not, the problem is your gas supply, not the furnace. At the furnace, the handle on the gas shutoff should run parallel to the pipe.

  6. Read the blinking light

    Most furnaces have a small light visible through a window in the lower door. It blinks a code when something is wrong, and the key to the code is on a sticker inside the door panel. Note the pattern before you call. It tells a technician where to start.

Stop and call if

  • You smell gas. Leave the house, then call your gas utility and 911 from outside.
  • A carbon monoxide alarm sounds. Get everyone out and call 911.
  • A breaker trips a second time
  • The burners light, then shut off after a few seconds, over and over
Call 832-484-9595

What it usually turns out to be

CauseSystemWhat the repair involves
Overheating from a clogged filterBothA new filter, which you can do. If the safety switch keeps tripping afterwards, it needs a look.
Dirty flame sensorGasThe burners light and drop out within seconds. A technician cleans or replaces the sensor.
Failed ignitorGasThe furnace tries to start and never lights. Part swap, usually on the same visit.
Burned-out heating elementElectricThe fan runs but one or more elements no longer heat. The element is replaced.
Failed sequencer or relayElectricThe part that switches the elements on in stages. Part swap.

Questions people ask us

The air is warm, just not hot. Is that a problem?

Possibly not. Air at the vent feels cooler than you expect because it is moving across your skin. If the house reaches the set temperature and holds it, the system is working.

Can I keep resetting the furnace to get it going?

Once is fine. A furnace that locks itself out is reporting a fault, and forcing it to retry repeatedly can turn a small problem into a larger one.

Is it safe to run a space heater until it’s fixed?

Yes, with care: plug it straight into a wall outlet, keep it three feet from anything that burns, and switch it off when you sleep or leave the room. Never heat a house with a gas oven or a grill.