Air conditioning
Check these first free
- Thermostat is set to Cool, and the fan is on Auto rather than On.
- Hold the air filter up to a light. If you can’t see through it, swap it.
- Look at the breaker panel. The outdoor unit has its own breaker, and it can trip while the indoor fan keeps blowing.
- Walk outside. Is the fan on top of the unit spinning?
What it usually is
A failed capacitor, a dirty outdoor coil, or refrigerant that has leaked out.
A capacitor is one of the quickest repairs we do. It rarely means you need a new system.
Call us if
- The breaker trips again after one reset
- The outdoor unit hums but the fan doesn’t spin
- You see ice on the copper line
Check these first free
- Thermostat screen blank? Replace its batteries.
- Reset both breakers: one for the indoor unit, one for the outdoor unit.
- Find the switch near the indoor unit that looks like a light switch. It should be on.
- Look in the drain pan under the attic unit. Standing water trips a safety switch that shuts everything down.
What it usually is
In Houston, most often a clogged drain line that has tripped the safety switch. After that: thermostat batteries, a capacitor, or a contactor.
Call us if
- A breaker won’t stay reset
- You smell something burning
- The pan is full and water is near the ceiling
Check these first free
- Turn the system off at the thermostat so it stops making water.
- Find the white PVC drain line at the indoor unit and pour a cup of white vinegar into the capped opening.
- Put a wet/dry vacuum on the end of the drain line outside and run it for a minute.
- Check the filter. A clogged one freezes the coil, and the ice turns into a puddle.
What it usually is
Algae in the condensate drain. Your AC pulls gallons of water out of Houston air every day, and all of it leaves through one three-quarter-inch pipe.
Call us if
- There’s a stain on the ceiling
- The drain pan has rusted through
- The clog comes back within a few weeks
Check these first free
- Switch cooling off and set the fan to On. Let it thaw for two to four hours.
- Don’t chip at the ice. The fins and tubing underneath bend and puncture easily.
- Put in a clean filter.
- Open every supply vent and move furniture off the return grille.
What it usually is
Not enough air moving across the coil (filter, dirty coil, weak blower), or low refrigerant from a leak.
Call us if
- It ices over again after a full thaw and a new filter
- You hear hissing or bubbling near the unit
Check these first free
- Work out which unit it is, indoor or outdoor, and whether it happens at start-up, while running, or at shut-off.
- With the power off at the outdoor disconnect, look for sticks or debris in the fan.
- Press on the cabinet panels. A loose screw makes a surprising amount of rattle.
What it usually is
Buzzing or humming points to a capacitor or contactor. Clicking that never leads to a start is usually the same.
Screeching is a fan motor bearing. Banging is a loose or broken part.
Shut it off and call if
- You hear banging, grinding or screeching. Running it can turn a small repair into a compressor.
Check these first free
- On a 100-degree afternoon, running most of the hour is normal. Judge it in the evening instead.
- Fan set to Auto, clean filter, outdoor coil free of grass and dirt.
- Hold a thermometer at a supply vent, then at the return. The supply air should be roughly 15 to 20 degrees cooler.
What it usually is
Dirty coils, low refrigerant, leaky attic ducts, or a system that was too small for the house from day one.
Call us if
- The house still hasn’t reached the set temperature by late evening
- Your electric bill jumped with no change in habits
Heating
Already have a repair quote?
If someone has told you what is wrong and what it costs to fix, the next question is whether the repair is worth making.
Or browse all 28 guides.