The short answer Put a wet/dry vacuum on the end of the drain line outside and run it for a minute or two. That pulls the clog out the way it was heading. Then pour a cup of white vinegar into the access opening at the indoor unit. Most clogs clear in fifteen minutes.
- Time
- 15 to 20 minutes
- You’ll need
- Wet/dry vacuum, white vinegar, a rag
- Cost
- A bottle of vinegar
Your air conditioner removes water from the air as it cools. In Houston that can be many gallons a day, and all of it leaves the house through one three-quarter-inch plastic pipe. Dust and algae grow in that pipe, and eventually they block it.
First, find both ends
- At the indoor unit: a white PVC pipe leaves the side of the unit. Near where it starts there is usually a short upright stub with a cap. That is the access opening.
- Where it ends: on many Houston homes the main drain ties into the plumbing under a bathroom sink. On others it runs outside and ends near the outdoor unit or at the foundation.
- The backup: a second pipe from the metal pan under an attic unit usually comes out high on an outside wall, often above a window. It is put there on purpose. If water is dripping from it, the main drain is already clogged.
Turn the system off
At the thermostat. It stops making water while you work.
Vacuum from the outside end
If the drain ends outdoors, hold the wet/dry vacuum hose over the end of the pipe and wrap a rag around the joint to seal it. Run the vacuum for one to two minutes. Check the canister: brown water and slime mean you got it.
If your drain ties into a sink instead, vacuum from the access opening at the indoor unit.
Flush with vinegar
Take the cap off the access opening and slowly pour in one cup of plain white vinegar. Leave it for thirty minutes. It kills the algae that caused the clog.
Rinse and test
Pour in a cup or two of water. It should disappear without backing up. If your drain ends outside, have someone watch for it coming out.
Empty the pan
If the metal pan under an attic unit has water in it, soak it up with towels or the vacuum. The float switch will not let the system restart while the pan is wet.
Turn the system back on
Replace the cap and set the thermostat to cool.
Use vinegar, not bleach. Bleach can damage the metal coil and pan if it splashes back, and it should never be mixed with other cleaners in a closed pipe.
Stop and call if
- Water will not go down after vacuuming and flushing
- There is a stain on the ceiling or wet insulation in the attic
- The metal pan is rusted through
- The clog returns within a few weeks
Keeping it clear
- Pour a cup of white vinegar into the access opening every month or two during cooling season.
- Change the filter on schedule. Dust that gets past a dirty filter ends up in the drain.
- Have the drain cleared and the pan checked at a spring tune-up.
- Glance at the backup drain outlet above the window now and then. Any drip from it is an early warning.
Questions people ask us
How do I know the drain line is the problem?
The usual signs are water in the pan under the attic unit, a drip from the pipe above a window, a system that shut itself off, or a wet patch on the ceiling below the unit.
Why does it keep clogging?
Either the line does not slope enough to drain fully, it has a sag that holds water, or the coil is dirty and shedding debris. Those need correcting at the source.
Can a clogged drain damage the AC?
Not the AC itself. The damage is to your house: ceilings, insulation and walls. That is what the float switch is there to prevent.